Oswald

Industrial

C-600HV

Product Specifications

Performance 

Maximum Flow/Pressure for C-600HV AC models: 

AC Model Max Feed Rate (at 0 psi) Max Speed Max Pressure Max Temp
GPD GPH LPH Oz/Min mL/Min SPM PSI(bar) °F(°C)
C-660HV 189 7.8 29.5 16.8 492.2 60 20 (1.4) 130 (54)
C-6125HV 398 16.5 32.4 35.3 1041 125 10 (0.7) 130 (54)
C-6250HV 791 32.9 124.5 70.3 2076 250 5 (0.4) 130 (54)

Maximum Flow/Pressure for C-600HV DC models: 

DC Model Max Feed Rate (at 0 psi) Max Speed Max Pressure Max Temp
GPD GPH LPH Oz/Min mL/Min SPM PSI(bar) °F(°C)
C-660HV 268 11.2 42.4 23.8 706.7 60 20 (1.4) 130 (54)
C-6125HV 568 23.7 89.7 50.5 1495 125 10 (0.7) 130 (54)
C-6250HV 1129 47.1 178.3 100.4 2972 250 5 (0.4) 130 (54)

Maximum Fluid Temperature: 130 °F (54 °C) 

Maximum Working Pressure: up to 20 psig (1.4 bar) (model specific) 

Maximum Viscosity: 1,000 Centipoise 

Maximum Suction Lift: 10 ft Water at Seal Level 

Electrical and Controls 

Electrical (Motor – Fixed Speed) Power Requirement:   

  • 115VAC 60HZ (.74 Amp Max) 
  • 220VAC 50HZ (.36 Amp Max) 20% less output 
  • 230VAC 60HZ (.31 Amp Max) 
  • 240VAC 50HZ (.27 Amp Max) 20% less output 
  • 24VAC 60HZ (3.4 Amp Max) 
  • 12 VDC (3. 0 Amp Max) 
  • 24 VDC (1.5 Amp Max) 

Inputs/Outputs 

  • None 

Materials of Construction 

Pump Head: Acrylic 

Adapters: PVC 

Valve Check/poppet: EP 

Poppit Spring: Hastelloy C 

Valve Seats:  EP 

Diaphragm: EP 

Enclosure: NEMA 1 (IP20) powder-coated zinc 

Strainer: PVC 

Suction/Discharge Tubing: ½” ID x 5/8” Clear PVC 

Dimensions and Weights 

Maximum Overall Dimensions:   

AC Models: 6.75” W x 7” H x 6.125” D ( 17.5 W x 17.78 H x 15.55 D cm) 

DC Models: 7.22” W x 7” H x 6.125” D (18.3 W x 17.78 H x  15.55 D cm) 

Product Weight: 8 Lb. (3.6 Kg) 

Approximate Shipping Dimensions: 10.5” W x 11.75” H x 13” D (26.7 W x 29.8 H x 33 D cm) 

Approximate Shipping Weight: 9 lb. (4.1kg) 

Agency Listings 

NSF 50 (Sodium Hypochlorite) 

UL 

CE  

CSA 

cETLus 

RoHS Compliant 

FAQs

Frequently Asked Questions

C-600HV Product Specifications

  • Why is the pressure so low on this pump series?

    The C600HV was designed to be a transfer pump. It will transfer chemical from one point to a nearby point that will not require high pressure capacities.

  • Ask me a question!
Processing... ...

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

To select or deselect multiple products–desktop users hold [ctrl] on Windows or [cmd] on Mac and click products.

Select Products

Pumps
Flow Meters
Skid Systems

Please review your selections before continuing.

Product Details
Select your industry:
How did you hear about us?

We'd like to hear from you...

ImageCatalog NumberDescriptionPriceBuy