Blue-White - Chemical metering and fluid measurement solutions; chemical metering pumps, peristaltic pumps, diaphragm pumps, multi-diaphragm pumps, flow meters, flowmeters, variable area flow meters, paddlewheel flow meters, ultrasonic flow meters, engineered skid systems, single skid system, duplex skid system, triplex skid system, water analyzers...
Oswald

Industrial

A3

Operation

Priming the Pump

Before priming the pump, or starting the pump, be sure that all suction and discharge lines are connected properly and that proper valves are open.  

Prime mode can be accessed by pressing the App Drawer key. Then press the “Prime” key to enter Prime mode.  In Prime mode, press the Start key. The pump will run at 100% speed for 60 seconds.  The pump can be stopped at any time by pressing the Stop key. 

Manual Speed Adjust

image 18

The initial/default mode of the pump will be “Manual Speed Adjust.”  Verify that you are in Manual Mode by noting the operating mode at the top of the touchscreen. Adjust pump speed by pressing the Up and Down arrow keys on the touchpad. Pump speed can also be adjusted by pressing the Settings key. Pump speed (flow rate, RPM) can be set to a specific value. 

Remote Start/Stop

If using the pump in Remote Start/Stop Mode (indicated by “RSS1” on the left side of the touchscreen), press the Start/Stop key to put the pump in “Standby” state. The display will read “STANDBY” if waiting for a signal from the user-provided control system. Once a signal is received, the pump will start.  

image 17

Other Operating Modes

To run the pump in other operating modes (4-20mA, Frequency, Pulse Input, Manual Cycle Adjust, Dispensing), press the App Drawer Key, and then press the desired operating mode key. Pump will go into desired run mode.   

Calibration

A blue circle with white text

Description automatically generated When in any of the operating modes, the pump can be calibrated by pressing the “Tube Calibration” key.  

image 19

To ensure the most accurate pumping, a pump calibration is recommended prior to operating the pump.  The A3S pump flow rate will vary depending on the suction line conditions. Calibrate the pump with actual suction line conditions.     

To calibrate the pump: 

  1. Connection tubing and open valves on the suction side of the pump to represent actual suction line conditions. 
  2. Set up discharge and open discharge valves to dispense into calibration column/cylinder. 
  3. Prime the pump, or run the pump in Manual Speed Adjust, pump so that the calibration column begins to fill. Stop the pump and note the solution level in the calibration column.  
  4. Put the pump into Calibration mode by pressing the “Tube Calibration” key.   
  5. Enter the desired calibration values for pump speed and run time in seconds.  
  6. Press Start key. 
  7. Pump will run for the time selected. Observe pump and calibration for proper filling. When the pump stops, measure the amount pumped by reading the calibration column level, noting the difference from starting position.   
  8. Enter the amount pumped on the screen and press enter. The pump will calculate maximum tube flow rate automatically. 
  9. The pump is now calibrated. Review calibrated Maximum Flow Rate by pressing Tube Calibration key.

Calibration results should be similar to the flow rating for the pump tube, but can vary depending on chemical composition, suction lift, viscosity, temperature, and other conditions.   

When a new tube is installed in the pump, we recommend running a calibration after the pump tube has broken in after approximately 30 minutes. 

Tube Failure Detection (TFD) and Tube Information

The A3S pump is equipped with leak-detection located inside the pump head.  If a tube fails or leaks for any reason, the chemical will trigger the sensor, stop the pump, and activate an alarm.  

If TFD alarm occurs, the pump will stop, close an alarm output, and the screen will flash with an red alarm. If the system has detected chemical, the pump tube must be replaced, and the pump head and roller must be thoroughly cleaned. 

Remove the front cover to replace the tube and roller. Failure to clean the pump head properly will void warranty. See video on proper tube replacement.   

A blue circle with white text

Description automatically generated At any time, tube information can be accessed by pressing the Tube Info key. 

image 22

The Tube Information screen will show: Tube Type installed, Tube install date, Tube run hours & revolutions, and current Maximum tube flow rate.  

FAQs

Frequently Asked Questions

A3S Operation

  • Can a pressure switch be used with this pump?

    Yes, a pressure switch can be used to open or close any number of electrical circuits of the pump. For one example, a pressure switch can be used to stop or start the pump by opening or closing the remote start/stop contact closure circuit protecting the pump from excessive pressure conditions.

  • What is a pressure switch?

    A pressure switch is a type of electrical switch that is designed to respond to changes in fluid pressure. It is commonly used in various applications to monitor and control the pressure of gases or liquids. When the pressure exceeds or falls below a predetermined set point, the switch activates or deactivates an electrical circuit, triggering the operation or shutdown of a connected device or system.

  • How do I increase pump output?

    For increased Max Feed Rate, there are a couple of options available. Firstly, replacing the pump tube and utilizing a compatible roller assembly that ensures proper alignment can lead to improved results. Additionally, another approach is to reduce the suction lift of the pump itself. This will also increase the out capacity of the pump. For more specific information and details, please get in touch with our customer service.

  • How do I trigger a dispense event? Can i remotely trigger the pump to dispense?

    The Dispense mode in the A3/A3S operates as a local mode, which does not respond to pulses for activation. Instead, it requires manual initiation by pressing the start button on the pump. On the other hand, the Pulse batch mode enables pulse acceptance and counting for batch dispensing. It allows the user to input a specific pulse count, and once that count is reached, the A3/A3S will dispense the predetermined amount of chemical programmed in the pump.

  • Can I stop the prime cycle before the 60 second time is up?

    Yes. Pressing the stop button will stop the prime cycle. 

Please click here to see help center disclaimers.

  • Ask me a question!

Processing... ...

Stay in the know

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

To select or deselect multiple products–desktop users hold [ctrl] on Windows or [cmd] on Mac and click products.

Select Products

Pumps
Flow Meters
Skid Systems
Analyzers

Please review your selections before continuing.

Product Details
Select your industry:
How did you hear about us?

We'd like to hear from you...

ImageCatalog NumberDescriptionPriceBuy