A3

FLEXFLO® Peristaltic Metering Pump

A3 peristaltic metering pump design does not have valves that can clog requiring maintenance, is self-priming, and cannot vapor lock or lose prime.
Technical Overview:

GPH .001 - 35.19 Enclosure Rating NEMA 4X (IP66)
LPH .003 - 133.2 Standards CE, cETLus, RoHS
PSI 125 Control Methods Manual, Remote Analog/Digital
Bar 8.6 Power Supply 100 to 240VAC-50/60Hz

Features

Benefits:
  • Self-priming – even against maximum line pressure. By-pass valves are not required. Cannot vapor lock or lose prime. 30ft of suction lift. Gentle low shear pumping action.
  • Tube Failure Detection (TFD) senses tube rupture by detecting chemical in the pump head. No false triggering – Patented
  • Optional dual channel tube design for optimum performance and pressure capability
Communication and Interface:
  • Operator friendly digital touch pad with menu driven software.
  • VGA Graphic multi-color backlit LCD displays remote/local control status, motor speed,
  • output rate, input signal values, service and alarm status.
  • Inputs include: 4-20mA, 0-10Vdc, and Pulse inputs for remote external speed control and 0-30 VDC / contact closure remote start/stop
  • Outputs include: Scalable 4-20mA or pulse, one 250V/6A relay and three 115V/1A contact closures assignable to monitor up to 17 different pump functions including TFD, FVS, remote/local control setting, motor on, fault, current operating mode, and others.
Superior Design:
  • 3 Year Warranty
  • 2,500:1 turndown ratio
  • NEMA 4X (IP66) wash-down, chemically resistant powder coated enclosure
  • Heavy duty rotor means no flexing and increased accuracy with no metal springs or hinges to corrode.
Safety Features:
  • Tube Failure Detection (TFD) senses tube rupture preventing hazardous chemical spills
  • Security programmable 4-digit password to prevent tampering
Optional Components Available:
  • Mounting Extended Brackets (72000-380) – 1 Pair, SS, 4 SS Screws
What’s Included:
  • A3 Peristaltic Metering Pump
  • Two tube assemblies
  • With “S” 3/8” OD x ¼” ID tubing compression type connections:
    • Suction tube – clear PVC – 10′ length (3/8″ OD, 1/4″ ID)
    • Suction strainer
    • Suction ceramic weight
    • Discharge tube – opaque polyethylene – 10′ length (3/8″ OD, 1/4″ ID)
    • Discharge injection fitting with check valve
  • With “B” ½” hose barb and “M” M/NPT type connections:
    • Suction strainer
    • Discharge injection fitting with check valve
    • #5 hose clamp (“B” Only)
  • With “C” Tri-clamp and “Q” Quick Disconnect connections:
    • No accessories provided
  • Tube installation tool
  • Mounting hardware kit
  • Junction box connectors

Specifications

Maximum working pressure (excluding pump tubes):
  • 125 psig (8.6 bar)
  • Note: see individual pump tube assembly maximum pressure ratings.
Maximum Fluid temperature (excluding pump tubes):
  • 185 F (85 C)
  • Note: see individual pump tube assembly maximum temperature ratings.
Ambient Operating Temperature
  • 14 F to 115 F (-10 C to 46 C)
Ambient Storage Temperature
  • -40 F to 158 F (-40 C to 70 C)
Approximate shipping wt:
  • A3 models: 33 lb. (15.0 Kg)
  • A4 models: 58 lb. (26.3 Kg)
Motor speed adjustment range:
  • 2,500:1 (0.04% – 100% motor speed)
Motor speed adjustment resolution:
  • 0.1% increments > 10% motor speed
  • 0.01% increments > 1% motor speed and < 10%
  • 0.001% increments < 1% motor speed
Maximum viscosity:
  • 12,000 Centipoise
Maximum suction lift:
  • 30 ft. Water, 0 psig (9.14 m, 0 bar)
Display
  • 3 color VGA backlit LCD, UV resistant.
Display Resolution
  • 0.1 > 10% motor speed
  • 0.01 > 1% motor speed and < 10%
  • 0.001 < 1% motor speed
Display Languages
  • English, Spanish, French or German selectable.
Keypad
  • Ten button positive action tactile switch keypad.
Security
  • Programmable 4-digit password.
Power Cord Options:
  • 115V60Hz = NEMA 5/15 (USA)
  • 230V60Hz = NEMA 6/15 (USA)
  • 220V50Hz = CEE 7/VII (EU)
  • 240V50Hz = AS 3112 (Australia/New Zealand)
Enclosure:
  • NEMA 4X (Ip66), Polyester powder coated aluminum.
  • Maximum Overall Dimensions:
  • A3 models: 8-1/8”W x 10-3/4”H x 15-1/4”D (20.6W x 27.3H x 38.9D cm)
  • A4 models: 12-1/8”W x 14-1/4”H x 18-5/8”D (30.8W x 36.1H x 47.3D cm)
Operating Voltage:
  • A3 MODELS:
  • 115VAC/60Hz, 1ph (2.0 Amp Maximum)
  • 230VAC/60Hz, 1ph (1.0 Amp Maximum)
  • 220VAC/50Hz, 1ph (1.0 Amp Maximum)
  • 240VAC/50Hz, 1ph (1.0 Amp Maximum)
  • A4 MODELS:
  • 115VAC/60Hz, 1ph (3.1 Amp Maximum)
  • 230VAC/60Hz, 1ph (1.6 Amp Maximum)
  • 220VAC/50Hz, 1ph (1.6 Amp Maximum)
  • 240VAC/50Hz, 1ph (1.6 Amp Maximum)

Videos

Accessories

You may also like…

Replacement Parts

ImageNameCatalog Number

Downloads

Title
A3 Replacement Parts List
17 downloads
77802 491 KB August 30, 2021
A3F A4F Instruction Manual – 80000-419
5202 downloads
38073 2.86 MB May 21, 2021
A3V A4V Instruction Manual – 80000-463
9547 downloads
46157 3.61 MB May 21, 2021
A3 A4 Technical Data Sheet – 85000-098
11923 downloads
46160 730 KB September 15, 2021
Flex-Pro A3 / A4 Engineering Spec Sheet
3306 downloads
48253 253.00 KB May 12, 2021
Industrial Tubing Selection Guide – 85000-120
16541 downloads
46161 0.98 MB August 5, 2021

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

Select your industry:
How did you hear about us?
Select your industry:
How did you hear about us?
Do you want to speak with a sales representative?