S6A

Digital Ultrasonic Flow Meter

Configurable via Blue-Central® desktop software range.

Technical Overview:

GPM Fahrenheit (°F)
LPM Celsius (°C)
PSI Body Material
Bar Pipe Sizes
Literature

Features

Benefits:
  • Inline pipe fittings for easy installation
  • Configurable via Blue-Central ® desktop software
  • Isolated 4-20 mA output – fully configurable
  • 0-10000Hz Pulse output – fully configurable
  • User configurable flow rate and total set-point triggers
  • Flow-rate readings as low as 10 mL/min
  • Included wetted end fittings allow for more than 14 inlet and outlet configurations
  • True unions for ease of maintenance
  • Wetted components constructed out of PVDF and PEEK
  • Process control via configurable solid state relay, which can be configured to close or open trigger at a flow-rate or to flow total for batching operation
  • Large 3.5” backlit LCD display.

Specifications

Electronics/Hardware

SPU (Signal Processing Unit):

Enclosure
  • NEMA 4X (IP66) Polycarbonate, SS hardware.
  • Dimensions: 10.02H x Ø3.79 inches (254.5H x Ø96.1 mm)
  • Weight 1.5 lb. (.68 Kg.)
Power Requirements
  • 5 VDC; 5 watts maximum
Environmental Conditions
  • Operating temp: 14 F to 104 F (-10 C to 40 C)
  • Storage: -40 F to 158 F (-40 C to 70 C)
  • Relative humidity: 0% – 90%
Software Language
  • English
Volume Units
  • Independently configurable Rate and Total units in: U.S. Gallons, Liters, or Milliliters.
Time Units
  • Seconds, minutes, hours, days.
Flow Rate Averaging
  • Selectable: 1, 4, 8, 16, and 32 seconds.
Data Outputs
  • Isolated 4-20 mA output – fully configurable
  • 0-10000 Hz Pulse output – fully configurable
Process Control
  • One Solid State Relay
  • Load capacity: 24VDC, 100mA max (ex. supplied)
  • Configure to flow rate for high/low/range rate trigger. Programmable release values enable auto release or manual latching operation.
  • Configure to flow total for automatically triggered, timed batch operations for proportional feed applications.
Power Supply (user configurable)
  • Includes each of the following:
  • U.S. Transformer, 115VAC 60HZ / 15VDC, NEMA 5/15 plug
  • Europe Transformer, 230VAC 50HZ / 15VDC, CEE 7/V11 plug
  • Australia / New Zealand Transformer, 240VAC 50HZ / 15VDC, AS 3112 plug
  • U.K. Transformer, 230VAC 50Z / 15VDC, BS 1363/A plug

Blue-Central® Software

Software Features
  • Configurable 4-20mA, Pulse Output, Frequency Output,
  • Solid State Relay Set-Point
  • Monitor flow rate in real time
  • Monitor total volume in real time
  • Monitor meter diagnostics
  • Field Upgradable Firmware
  • Factory Resettable
  • TDS #85000-137 rev.17 20191203
Compatible Operating Systems
  • Windows 7, 8, and 10
  • Mac (OSX 10.11/10.12/10.13)
Computer Connector
  • USB-C (USB-A to USB-C cable included)

Wetted Materials

Transducer
  • PEEK
Body
  • PVDF & PEEK
O-Rings
  • TFE/P
  • EP
Fittings (Included)
  • PVDF 1/2” I.D. Barb
  • PVDF 1/2” I.D. Barb Elbow
  • PVDF 1/2” M/NPT
  • PVDF 1/2” M/NPT Elbow
  • PVC 1/2” Slip

General Operation

Pre-Calibrated Chemical Profiles
  • Water
  • Aqueous Ammonia
  • Ammonium Hydroxide
  • Ferric Chloride 40%
  • Sodium Bisulfite 40%
  • Sodium Hypochlorite 12.5%
  • Sodium Permanganate
  • Hydrofluorosilicic Acid 25%
  • Ammonium Sulfate 10%
Compatible Fluid Types
  • Acoustically conductive fluids
  • Particulate and bubbles with 50,000 ppm or less

Videos

Replacement Parts

ImageNameCatalog Number

Downloads

Title
S6A Meter Mount Display Quickstart Guide – 80000-604
1 file(s) 596 downloads
49957 June 18, 2021
S6A Quickstart Guide – 80000-595
1 file(s) 569 downloads
49741 June 18, 2021
S6A Instruction Manual – 80000-594
1 file(s) 1606 downloads
49275 June 24, 2021
S6A Technical Data Sheet – 85000-137
1 file(s) 2492 downloads
49273 July 28, 2021
Select your industry:
How did you hear about us?