A-100N

FLEXFLO® Peristaltic Metering Pump

Peristaltic pump design does not have valves that can clog requiring maintenance, is self-priming, and cannot vapor lock or lose prime.

Technical Overview:

GPD
2.4 - 124.08
LPH
.4 - 20
PSI
100
Bar
6.9
Enclosure Rating
NEMA 3R (IP23)
Standards
NSF/ANSI 61, CE, cETLus, RoHS
Control Methods
Manual, Remote Analog/Digital
Power Supply
100 to 240VAC-50/60Hz
Overview

Key Features

Overview

  • Patented TFD (Tube Failure Detection) system protects against chemical spills from a worn out tube and activates an alarm output relay
  • Self-Priming against maximum line pressure
  • Cannot Vapor Lock or Lose Prime
  • Tube material options: Norprene®, Norprene® Chemical, and Tygothane®
Performance Data

Output Table

Tube Model Max Pressure 14 RPM Models 30 RPM Models 45 RPM Models 60 RPM Models*
PSI (bar) GPD GPH Oz/Min ML/Min LPH GPD GPH Oz/Min ML/Min LPH GPD GPH Oz/Min ML/Min LPH GPD GPH Oz/Min ML/Min LPH
1 65(4.5) 5.7 0.24 0.51 15 0.90 13.3 0.55 1.18 35 2.1 20.5 0.86 1.83 54 3.24 25.5 1.06 2.26 67 4.02
2 65(4.5) 12.2 0.51 1.08 32 1.92 28.5 1.19 2.54 75 4.5 43.6 1.82 3.89 115 6.90 53.3 2.22 4.73 140 8.40
3 50(3.5) 27.8 1.16 2.47 73 4.37 65.8 2.74 5.85 173 10.38 99.2 4.14 8.82 261 15.66 124 5.17 11.01 326 19.56
4 100(6.9)* 2.3 0.10 0.20 6.0 0.36 4.9 0.21 0.44 13 0.78 8.0 0.33 0.71 21 1.26 9.5 0.40 0.85 25 1.50
6 100(6.9)* 6.9 0.30 0.60 18.1 1.10 16.0 0.67 1.42 42.1 2.5 24.0 1.0 2.13 63.1 3.8 30.1 1.25 2.67 79.2 4.7
7 50(3.5) 21.7 0.90 1.92 57.0 3.40 52.5 2.19 4.66 138 8.3 76.1 3.17 6.76 200 12.0 95.1 3.96 8.45 250 15.0
8 50(3.5) 15.2 0.63 1.35 40.0 2.40 31.9 1.33 2.84 84 5.04 53.3 2.22 4.73 140 8.4 68.4 2.85 6.10 180 10.8
* See pressure rating for specific tubes. Note: -4, -6 Tubes max pressure for 60 rpm model is 75 psi.
Flex-A-Thane = 1, 2, and 3 tubes. Flex-A-Prene = 4, 6, and 7 tubes. Flex-A-Chem = 8 tube.
Technical

Specifications

Max. Working Pressure
Up to 100 psig (6.9 bar) (see specific tube ratings in the Output Table)
Max. Fluid Temperature
130° F
54° C
Ambient Temperature Range
14 to 110° F/ -10 to 43° C
Max. Viscosity
5,000 Centipoise
Max. Suction Lift
30 ft. Water at sea level
14.7 psia
Operating Voltage
  • 115VAC/60Hz, 1ph (14 & 30 RPM = 1.37 Amp Max.; 45 & 60 RPM = 1.87 Amp Max.)
  • 220VAC/50Hz, 1ph (14 & 30 RPM = 0.68 Amp Max.; 45 & 60 RPM = 1.14 Amp Max.)
Power Cord Options
  • 115V 60Hz = NEMA 5-15 (USA)
  • 220V 50Hz = CEE 7/VII (EU)
Motor
Variable Speed DC
Duty Cycle
Continuous
Flow Adjustment Range
0.1 – 124 GPD
0.3 – 326 mL/min
Output Adjustment Range
  • 10% – 100% motor speed (5% -100% on certain models)
  • NOTE: 14 RPM & 30 RPM Models with 1, 2, or 4 tubes have 20:1 turndown.
Solids
50% by volume
Programmable Input (V Model Only)
4-20 mA, 0-10 VDC, Pulse/Frequency
TFD+ (Tube Failure Detection)
Patented sensor. Will stop pump and activate contact closure on “V” model, and open collector output on “F” model (6-30vdc collector voltage. 50mA max sinking current.)
FVS (Flow Verification System)
Compatible with optional pulse flow sensor. Will stop pump and activate open collector output. 6-30VDC collector voltage. 50mA max sinking current. Contact factory for sensor options.
Motor Active
Motor active – open collector output. 6-30VDC collector voltage. 50mA max sinking current.
Enclosure
NEMA 3R, IP23
Product Weight
8 lb.
3.63 kg
Approximate Shipping Weight
10 lb.
4.5 kg
RoHS Compliant
Yes
Standards
CE, cETLus, NSF/ANSI 61
must be specified in model number
Order Information

Configure Pump

Purchase

Accessories

Purchase

Replacement Parts

ImageCatalog NumberDescriptionPriceBuy
Documentation

Downloads

Title Type Size Updated Download
Instruction Manual 3 files
A-100N (F, V) Instruction Manual – 80000-381 PDF 9.88 MB Dec 31, 2025 Download
A-100NA (C, S, X) Instruction Manual – 80000-327 PDF 9.51 MB Aug 26, 2025 Download
A-100N (FP, VP) Instruction Manual – 80000-587 [LEGACY] PDF 722.88 KB Feb 10, 2026 Download
Technical Data Sheet 7 files
A-100NV Technical Data Sheet – 85000-040 PDF 656.38 KB Aug 12, 2025 Download
A-100NA Technical Data Sheet – 85000-038 PDF 522.63 KB Nov 11, 2026 Download
A-100NF Technical Data Sheet – 85000-043 PDF 633.15 KB Aug 12, 2025 Download
A-100N Technical Data Sheet – 85000-197 PDF 1.07 MB Nov 11, 2026 Download
A-100N Polymer Technical Data Sheet – 85000-196 [LEGACY] PDF 1.02 MB Feb 10, 2026 Download
A-100NVP Technical Data Sheet – 85000-132 PDF 2.49 MB Aug 12, 2025 Download
A-100NFP Technical Data Sheet – 85000-131 PDF 2.48 MB Aug 12, 2025 Download
Guides 1 file
A-100N Quick Start Guide – 80000-738 PDF 330.61 KB Dec 2, 2025 Download
Brochure 1 file
Aquatics Comparison Chart PDF 1.73 MB Mar 16, 2026 Download
Catalog 1 file
Industrial Catalog 2026 – 80000-707 PDF 17.00 MB Jul 2, 2026 Download
Legacy 2 files
A-100N (FP, VP) Instruction Manual – 80000-587 [LEGACY] PDF 722.88 KB Feb 10, 2026 Download
A-100N Polymer Technical Data Sheet – 85000-196 [LEGACY] PDF 1.02 MB Feb 10, 2026 Download
Replacement Parts List 1 file
A-100N Replacement Parts List PDF 1.33 MB Feb 10, 2022 Download

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

Select your industry:
How did you hear about us?
Select your industry:
How did you hear about us?

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

To select or deselect multiple products–desktop users hold [ctrl] on Windows or [cmd] on Mac and click products.

Select Products

Pumps
Flow Meters
Skid Systems

Please review your selections before continuing.

Product Details
Select your industry:
How did you hear about us?